Acculoc RHW A002 With Infant Trolley IT1000

Infant Warmer With Seprate Trolley

₹48000.00₹33500.00

Out of stock

Type                                                                        Radiant Warmers


Material                                                                  Metal


Model Name/Number                                          RHW A002


Brand                                                                       ACCULOC


Color                                                                        NA


Voltage                                                                    220V AC


Height                                                                      na


Width                                                                        na


Assay Time                                                             Minna


Temperature                                                           Skin and Air Servo Controlled


Length Mm                                                              na


Light Source                                                            na


Number Of Wheels                                                 4


Power V                                                                   220VAC


Temp Range Deg                                                   Celsius38


Weight                                                                     55kgs


Country of Origin                                                   Made in India

OPERATING MODES  SKIN MODE: In Skin mode heater power is controlled with reference to Skin probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.  AIR MODE: In Air mode heater power is controlled with reference to Air probe. In case when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off.   MANUAL: MODE In manual mode user can control heater manually. In this mode user can adjust heating speed (0 to 8 speed) and set timer upto 59min. With probes installed when the temperature exceeds Max ( 38 °C or 101 °F) in any probe Heater is turned off. Special attention is needed while operating without
ALERTS  Power fail: Power fail indicator turns ON with sound alert (cannot be muted).  Probe fail: Probe fail indicator turns ON with sound alert (can be muted). Displays “-.-.-“on temp display.  Heater overload: Heater overload indicator turns ON.  Low temperature: Low alarm indicator turns ON with sound alert (can be muted). Displays blinks.  High temperature: High alarm indicator turns ON with sound alert (can be muted). Displays blinks.  Manual mode Time out: Short sound alert and timer flashing on LCD.